50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer
When voltage acts on piezoelectric ceramics, mechanical deformation will occur with the change of voltage and frequency. On the other hand, when piezoelectric ceramics are vibrated, an electric charge will be generated. Using this principle, when an electrical signal is applied to a vibrator composed of two piezoelec…
50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer
When voltage acts on piezoelectric ceramics, mechanical deformation will occur with the change of voltage and frequency. On the other hand, when piezoelectric ceramics are vibrated, an electric charge will be generated. Using this principle, when an electrical signal is applied to a vibrator composed of two piezoelectric ceramics or a piezoelectric ceramic and a metal plate, called a double piezoelectric chip element, ultrasonic waves will be emitted due to bending vibration. On the contrary, when ultrasonic vibration is applied to a dual piezoelectric chip element, an electrical signal will be generated. Based on the above functions, piezoelectric ceramics can be used as ultrasonic sensors.
spec | Dimension (mm) | Radial frequency (KHz) | Capacitance (pf) | Dielectric dissipation factor tanδ(%) | Electromechanical coupling coefficient (Kr) | Impedance Zr(Ω) | Thickness frequency (KHz) |
PU-PC25103 | Φ25×Φ10×3 | 66.4 | 1240±12.5% | ≤0.3 | ≥0.46 | ≤15 | 683±5% |
PU-PC225104 | Φ25×Φ10×4 | 66.4 | 930±12.5% | ≤0.3 | ≥0.46 | ≤15 | 512±5% |
PU-PC40155 | Φ40×Φ12×5 | 45.9 | 2070±12.5% | ≤0.3 | ≥0.46 | ≤15 | 410±5% |
PU-PC40155 | Φ40×Φ15×5 | 42.2 | 1960±12.5% | ≤0.3 | ≥0.46 | ≤15 | 323±5% |
PU-PC40176 | Φ40×Φ17×6 | 40.5 | 1555±12.5% | ≤0.3 | ≥0.46 | ≤15 | 341±5% |
PU-PC40205 | Φ40×Φ20×5 | 37.9 | 1700±12.5% | ≤0.3 | ≥0.47 | ≤15 | 410±5% |
PU-PC50206 | Φ50×Φ20×6 | 33.2 | 2490±12.5% | ≤0.3 | ≥0.46 | ≤15 | 341±5% |
PU-PC501765 | Φ50×Φ17×6.5 | 34.8 | 2430±12.5% | ≤0.3 | ≥0.46 | ≤15 | 315±5% |
PU-PC50236 | Φ50×Φ23×6 | 31.2 | 2340±12.5% | ≤0.3 | ≥0.47 | ≤15 | 341±5% |
PU-PC50276 | Φ50×Φ27×6 | 29.3 | 2100±12.5% | ≤0.3 | ≥0.47 | ≤15 | 341±5% |
PU-PC603010 | Φ60×Φ30×10 | 25.3 | 1922±12.5% | ≤0.3 | ≥0.47 | ≤18 | 205±5% |
50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer
标签:20khz/15khz High Power Ultrasonic Transducer, 50*20*5mm PZT-8 Piezoelectric Ceramic Ring, High power ultrasonic transducer, Piezoelectric Ceramic Ring, piezoelectric ceramics
Send Inquiry
- 38*15*5mm PZT-8/PZT-4 Piezoelectric Ceramic Ring For 60W/100W 40khz/28khz Ultrasonic Cleaner Transducer
- Piezoelectric Ceramic Element Ultrasonic Piezoelectric Ring Pzt Piezo Ceramic Disc Piezo Ceramic For Cleaning Ring And Welding Ring
- Piezo Ring PZT8 60*30*10mm Piezo Ultrasonic Transducer For Welding Ultrasonic Welding For Mask Machine
- 38*15*5mm P81 Ultrasonic Piezo Element Piezoelectric Ceramic Ring For Ultrasonic Piezo Transducer
- PZT4 PZT5 PZT8 Customization 40mm Ultrasonic Piezo Transducer Ceramic Element Piezoelectric Sensor
- Piezoceramic Ring 10x5x2mm Custom Piezoceramic Ring For Ultrasonic Welder
- 45*15*5 Pzt Piezo Ceramic Element Piezo Crystal Ring Ultrasonic Piezo Ceramic Element Cylinder
- PZT8 Piezo Disk Element Discs Cleaning Welding Piezoelectric Ceramic Chip Ring
- 50*20*6 PZT8 Piezoelectric ceramic chip Ultrasonic Piezoelectric ceramic sheet Transducer chip Spot
- Piezoelectric Crystal Ring Element UltrasonicPiezo Ceramic PZT 4 Material Piezoelectric Sensor Ultrasonic Ceramic Ring
- 10x5x2mm PZT-8/PZT-4 Piezoelectric Ceramic Ring For 33khz 50W Medical Teeth Cleaning Ultrasonic Transducer
- 50*20*5mm PZT-8 Piezoelectric Ceramic Ring For 2000W 20khz/15khz High Power Ultrasonic Transducer